Human Laminin Gamma 2 (LAMC2) ELISA Kit, 96 well plate

Quick contact, quick delivery, greatests product price.

Size

5x96T

Catalog no

EKU05562
product photo

Click and buy. Our professional team will take care of your order immediately.

Get on Gentaur.com

Assay principle

The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Laminin Gamma 2 (LAMC2). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Laminin Gamma 2 (LAMC2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Laminin Gamma 2 (LAMC2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Laminin Gamma 2 (LAMC2) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Description

A microtiter plate (spelled Microtiter is a registered trade name in the United States) or microplate or micro well plate or multiwell, is a flat plate with multiple "wells" used as small test tubes. The microplate has become a standard tool in analytical research and clinical diagnostic testing laboratories. A very common usage is in the enzyme-linked immunosorbent assay (ELISA), the basis of most modern medical diagnostic testing in humans and animals. A microplate typically has 6, 24, 96, 384 or 1536 sample wells arranged in a 23 rectangular matrix. Some microplates have even been manufactured with 3456 or 9600 wells, and an "array tape" product has been developed that provides a continuous strip of microplates embossed on a flexible plastic tape.

Properties

E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.

ELISA's stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Precision of the test

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Laminin Gamma 2 (LAMC2) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Laminin Gamma 2 (LAMC2) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV

Warnings

The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

Storage recommendation

-20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

ELISA's specificity

This assay has high sensitivity and excellent specificity for detection of Laminin Gamma 2 (LAMC2). No significant cross-reactivity or interference between Laminin Gamma 2 (LAMC2) and analogues was observed.

Alternate gene name

B2T; EBR2; EBR2A; LAMB2T; LAMNB2; Kalinin/nicein/epiligrin 100 kDa subunit; Cell-scattering factor 140 kDa subunit; Ladsin 140 kDa; Large adhesive scatter factor 140 kDa

ELISA's cross-reactivity

This assay doesn't seem to cross-react with other species. For more information about cross-reactivity please contact us.

QC

The Kit is manufactured at ISO 9001 and ISO 13485 certified facilities.

Test

ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED

Samples to be analyzed

Serum, plasma, tissue homogenates and other biological fluids

Notes

For research use only. Not for diagnostic procedures.

Protocol

Please see ELISA's datasheet, otherwise contact us

Alternate protein number

Please refer to SwissProt

Research main area

Developmental science;

Verified reactivity

Homo sapiens (Human)

Estimated production time

7-11 business days

Detection limits

15.62-1000 pg/mL

Gene name

Laminin Gamma 2

ELISA detection

Colorimetric

Sensitivity limit

6,7 pg/mL

Assay class

Sandwich

Use for

8 months

Shipping requirements

Blue ice

Assay duration

3 hours

Protein number

Q13753

Verified applications

ELISA

Gene number

3918

We'd like to talk with you about your business and needs.

Contact Us